Product Model :
MR-2216DOutput Port :
16 PortsProtocol :
DMX512Power Input :
AC100~240VRated Power :
15WMAX Upload :
24,576ChannelsDimensions :
303*155*65mmControl Mode :
Sub-ControllerFeatures
1. MR-2216D Standard USITT DMX512/1990 General Grotocol and Extended Protocol;
2. MR-2216D Support Unlimited Cascade Transmission, Unlimited Number;
3. Independent Brightness Control of 3 Primary Colors, Easy to Adjust White Balance;
4. Support R,RB,RGB,RGBW,RGBWY, and Multi-Color Mixing Control;
5. Support 32-65536 Grayscale 16Bit, Support 262144 Grayscale, Restore image Details;
6. Accurate Gamma Correction Algorithm, in Line With Human Visual Sense;
7. Support Opening and Closing the Function of Writing DMX Addresses and Parameters;
8. Support 120Hz Frame Rate to Ensure High-definition Display and 3D Requirements;
9. Using Ethernet Interface and UDP Protocol, The Distance is 100 Meters;
10. LCD Display Module Displays Controller Parameters and Status in Time;
11. Support The Device ID Number Data Flow Sequence and Fixed Arrangement;
12. Two RJ45 Ports, Support Mixed Cascading; Automatic Software Display Status;
13. Support IP Grouping Function, use Switch Parallel Scheme;
14. 16-Port OutPut, Single Channel 512 Channels, ExpansionNeeds to BeTested by Itself;
15. Support Backup, Single Device Failure or Network Cable Disconnection Has no Effect;
16. Support Device Port Anti-interference and Leakage Design;
17. Support Overcurrent and Overvoltage Protection, Can run for a Long Time;
18. Network Adaptive or Mandatory 100M Can be Set to Support More Loading;
19. Equipment Network Port, Port OutPut, Surge Protection: 1.5KV;
20. Support Severe Working Environment -40℃-80℃, Normal Operation Without Failure.
21. Supports Online One-Click Upgrade of Device Firmware.
II. Output Port Definition
MR-2216D Controller Uses 16-Port 3Pin Terminal Interface OutPut Signals.
3Pin Terminals Sort Sequentially From Left to Right, As Shown Below:
Remark:④⑤ is 3Pin Port Fixing Screw Holes, Not a Signal Terminal.
III. Controller Three View Size Chart
MR-2216D Front View:
Remark:Above Three Views The Size Unit is mm.
IV. Basic Parameter Table
Install and Use
I. Online Mode (Connected With The Computer )
MR-2216D Controllerd Connect With The Computer Ethernet Port,as Shown Below:
II. Offline Mode
MR-2216D Connect With the Offline Master Controller,as Shown Below:
III. Integrated Synchronous and Asynchronous Mode
Connect With the Computer and The Main Control (Online Priority. No Signal Switch Offline), as Shown in The Following Figure: